Abstract


A performance test has been conducted of k0-NAA and relative methods for analysis of Al, Mg, K nuclides in SRM lake sediment sample (SRM SL-3). The performance test included validation, accuracy and precision tests, as well as t and F test. This test is done in order to know the performance of the both methods. Test results on validation test of both the k0-NAA and relative methods obtained were still in good performance with z-score values within the range of -2 ≤ x ≤ 2, in the accuracy and precision test showed that the two methods used were still reliable or passed the test for elemental analysis. The results of the evaluation t-test were at 95% confidence level showed that both methods were no significant differences in the test results, and the evaluating the F test showed that there are no differences in the accuracy between the two methods. The performance test data are expected to be used by practitioners and users of neutron activation analysis services as the reference option of analysis method to optimize the objectives to be achieved.

Keywords


performance test; NAA; relative method; k0-NAA; SRM SL-3

Full Text:

Full Text PDF


References

[1] Alhasan, E., Agbemava, S.E., Adoo, N.A., Agbodemegbe, V.Y., Bansah, C.Y., Della, R., Appiah, G.I., Kombat, E.O., and Nyarko, B.J.B., 2011, Setermination of trace element in Ghanaian Shea butter and Shea nut by neutron activation analysis (NAA), Res. J. Appl. Sci., Eng. Technol., 3 (1), 22–25.

[2] Bouhilaa, Z., Mouzai, M., Azli, T., Nedjar, A.,Mazouzi, C., Zergoug, Z., Boukhadra, D., Chegrouche, S., and Lounici, H., 2015, Investigation of aerosol trace element concentration nearby Algiers for environmental monitoring using instrumental neutron activation analysis, Atmos. Res., 166, 49–59.

[3] Lestiani, D.D., and Santoso, M., 2011, Analytical methods INAA and PIXE applied to characterization of airborne particulate matter in Bandung, Indonesia, Atom Indonesia, 37 (2), 52–56.

[4] Baidoo, I.K., Dampare, S.B., Opata, N.S., Nyarko, B.J.B., Akaho, E.H.K., Quagraine, R.E., 2013, Determination of aluminium, silicon and magnesium in geological matrices by delayed neutron activation analysis based on k0-INAA, Appl. Radiat. Isot., 82, 152–157.

[5] De Oliveira, K.A.P., Menezes, M.A.B.C., Jacomino, V.M.F., and Von Sperling, E., 2013, Use of nuclear technique in samples for agricultural purposes, Eng. Agríc., Jaboticabal, 33 (1), 46–54.

[6] Hamidatou, L.A., Dekar, S., and Boukari, S., 2012, k0-NAA quality assessment in an Algerian laboratory by analysis of SMELS and four IAEA reference materials using Es-Salam research reactor, Nucl. Instrum. Methods Phys. Res. A, 682, 75-78.

[7] Acharya, R., Holzbecher, J., and Chatt, A., 2012, Determination of k0-factor of short-lived nuclides and application of k0-NAA to selected trace elements, Nucl. Instrum. Methods Phys. Res. A, 680, 1–5.

[8] Greenberg, R.R., Bode, P., De Nadai Fernandes, E.A., 2011, Neutron activation analysis: A primary method of measurement, Spectrochim. Acta, Part B, 66 (3-4), 193–241.

[9] Baldo, I.K., Nyarko, B.J.B., Akaho, E.H.K., Dampare, S.B., Sogbadji, R.B.M., and Poku, L.D., 2013, Characterization of low power research reactor neutrons for the validation of k0-INAA standardization based on k0-IAEA software, Appl. Radiat. Isot., 79, 85–93.

[10] González, A.G., and Herrador, M.A., 2007, A practical guide to analytical method validation, including measurement uncertainty and accuracy profiles, TrAC, Trends Anal. Chem., 23 (3), 227–238.

[11] L’Annunziata, M.F., 2012, Handbook of Radioactivity Analysis, 3rd Ed., Academic Press, Netherlands.

[12] Supriyanto, C., Samin, and Sunardi, 2011, Perbandingan analisis unsur Cu, Cr dan Fe dalam cuplikan biota menggunakan metode AANC dan SSA, Jurnal Sains dan Teknologi Nuklir Indonesia - JSTNI, 12 (1), 39–50.

[13] Sunardi, 2008, Training report on nuclear analytical techniques (NATs) at radiochemistry Division, Bhabha Atomic Research Centre, Department of Atomic Energy, Mumbai, India

[14] Acharya, R., Dasari, K.B., Rao, J.S., Subramani, C.R.V., and Reddy, A.V.R., 2013, Characterization of irradiation sites of APSARA reactor for k0-based IM-NAA and its validation and application, IEEE Trans. Nucl. Sci., 60, 3051–3056.

[15] Faisal, W., and Nuraini, E., 2010, Validasi metode AANC untuk pengujian unsur Mn, Mg dan Cr pada cuplikan sedimen di sungai Gajahwong, GANENDRA Majalah IPTEK Nuklir, 13 (1), 27–36.

[16] Ardeniswan, 2011, Uji banding metoda pelindian logam krom cararotary agitator dengan ultrasonic cleaner menggunakan bahan acuan tanah bersertifikat, Jurnal Kimia Terapan Indonesia, 13 (1), 32–39.



DOI: https://doi.org/10.22146/ijc.24187

Article Metrics

Abstract views : 2500 | views : 2048


Copyright (c) 2017 Indonesian Journal of Chemistry

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

 


Indonesian Journal of Chemistry (ISSN 1411-9420 /e-ISSN 2460-1578) - Chemistry Department, Universitas Gadjah Mada, Indonesia.

Web
Analytics View The Statistics of Indones. J. Chem.