Abstract

Experiment to investigate the mechanism of boiling heat transfer in a narrow gap on severe accident scenarios of TMI-2 nuclear power plant is necessary to develop the understanding of the related accident management.The present study aimed to obtain heat flux value and critical heat flux (CHF) during boiling heat transfer process in a narrow gap of annulus. The study was experimentally carried out using the HeaTiNG 01 test with water as cooling fluid which temperature was varied at 75°C, 85°C dan 95°C. The rod was heated to 650°C. The boiling process during cooling was investigated by recording the transient temperature of the heated rod. The data was used to calculate the heat flux and wall superheat which results were represented in a boiling curve. The experimental results showed that the CHF value of the cooling media at 75°C was lower compared with that of at 85°C and 95°C. It was found that the values of CHF at 85°C and 95°C were close. The maximum CHF value at 75°C was 230 kW/m2 , while at 95°C was 282 kW/m2 . The CHF values at various position of heated rod was found to follow polynomial correlation. By comparing the boiling film areas from experimental results with that of Bromley correlation, it was concluded that boiling process in a narrow gap could not categorized as pool boiling process

References

  1. Bromley, L.A., 1950. Heat transfer in stable film boiling, Chemical Engineering Program, 46-221.
  2. Chunlin, Xia, et al., 1996. Natural convection in vertical rectangular narrow channels, Eksperimental Thermal and Fluid Scinece, 12, 313-324.
  3. G. Satish, M. Shoji, K. Vijay, Vijay K. Dhir, 1999. Handbook of Phase Change: Boiling and Condensation, Taylor and Francis, 64.
  4. Juarsa, M., dan Antariksawan, A. R., 2008. Efek Batasan Counter Current Flow Pada Perpindahan Panas Pendidihan Dalam Celah Sempit, Jurnal Teknologi Reaktor Nuklir Tri Dasa Mega 1 (1).
  5. Juarsa, M., Umar, E., Harto, A.W., 2009. Analisis fluks kalor pada celah sempit anulus berdasarkan tiga variasi suhu awal menggunakan bagian uji heating-01, Seminar Nasional Pengembangan Penelitian Dasar, Bandung, Indonesia.
  6. Monde, M., Kusuda, H. dan Uehara, H., 1982. Critical heat flux during natural convective boiling in vertical rectangular channels submerged in saturated liquid, Transactions of the ASME 104, 300-303.
  7. Nukiyama, S., 1934. Maximum and Minimum Values of Heat Transmitted from Metal to Boiling Water under Atmospheric Pressure, Journal of The Japanese Society of Mechanical Engineering 37, p. 367.
  8. Tanaka, F., Juarsa, M., Mishima, K., 2003. Experimental study on transient boiling heat transfer in an annulus with a narrow gap, Proc. of ICONE 11, France.
  9. US. NRC, 2007. The Accident At Three Mile Island, http://www.nrc.gov.
  10. Zang, J., Tanaka, F., Juarsa, M., Mishima, K., 2003. Calculation of boiling curves during rewetting of a hot vertical narrow channel, The 10th International Topical Meeting on Nuclear Reactor Thermal Hydraulics, 5-9 Oktober 2003, Korea