Wireless Data Logger Suhu Multi Channel Menggunakan Labview

  • Siswo Wardoyo Universitas Sultan Ageng Tirtayasa
  • Arya Prasetyo Habibie Universitas Sultan Ageng Tirtayasa
  • Romi Wiryadinata Universitas Sultan Ageng Tirtayasa
Keywords: Termokopel, wireless, data logger, multichannel

Abstract

Temperature is one of the physical quantities which are often used in control systems. The process of monitoring temperature in the form of a data logger is an important thing that is needed in the industry. This paper designs a wireless temperature data logger with multichannel input. Thermocouple is used as sensor input on this system. The results of this research indicate that the system is able to work wirelessly with a range of 300 meters until 800 m. Result of temperature measurement accuracy of the designed system is 99.419% or error temperature measurement against a reference temperature is 0.581%. Accuracy of voltage measurement towards Labview is 99.316% or error of 0.684%. The output file from data logger is file.tdms, which can be accessed by Microsoft Excel to be printed or processed further.

References

D. Nurmalasari, R. T. Wahyuni, and Y. Palapa, “Informational Dashboard untuk Monitoring Sistem Drainase secara Real-Time,” J. Nas. Tek. Elektro dan Teknol. Inf. UGM, vol. 4, no. 3, 2015.

R. S. Vivek Kumar Sehgal, Nitin, Durg Singh Chauhan, “Smart Wireless Temperature Data Logger Using,” IEEE Region 10 Conference (TENCON) - Hyderabad, India, 2008, pp. 1–6.

I. A. R. Djambiar, “Aplikasi labview pada sistem akuisisi data berbasis mikrokontroler,” Prosiding Seminar Penelitian dan Pengelolaan Perangkat Nuklir, 2008, pp. 406–410.

H. D. Wahjono, “Sistem Manajemen Komunikasi Data Jarak Jauh Berbasis Teknologi Sms Dan Radio Telemetry,” J. Air Indones. BPPT, vol. 4, no. 1, pp. 88–96, 2008.

S. Wardoyo, R. Munarto, and P. Putra, “Rancang Bangun Data Logger Suhu Menggunakan Labview,” Elit. Tek. Elektro PNJ, vol. 4, no. 1, pp. 23–30, 2013.

S. K. Estiko Rijanto, Rachman Soleh, “Rancang Bangun Pengkondisi Sinyal Termokopel Tipe K yang Mudah Di Tuning,” PPI-KIM LIPI, Serpong, pp. 201–211, 2004.

J. Marcin, “An-369 application note,” http://www.analog.com, 1998.

I. Dinata and W. Sunanda, “Implementasi Wireless Monitoring Energi Listrik Berbasis Web Database,” JNTE Univ. Andalas, vol. 4, no. 1, pp. 83–88, 2015.

R. Anugrah, “Sistem Pelacak Bus Kampus Dengan Menggunakan Modul DT-15 LCMS dan Wireless YS 1020 RF Data Transceiver,” Universitas Indonesia, 2008.

A. D. One Technology Way, “Monolithic Thermocouple Amplifiers with Cold Junction Compensation,” http://www.analog.com, 1999. .

S. Sawidin, O. E. Melo, and T. Marsela, “Monitoring Kontrol Greenhouse untuk Budidaya Tanaman Bunga Krisan dengan LabView,” J. Nas. Tek. Elektro dan Teknol. Inf. UGM, vol. 4, no. 4, 2015.

How to Cite
Siswo Wardoyo, Arya Prasetyo Habibie, & Romi Wiryadinata. (1). Wireless Data Logger Suhu Multi Channel Menggunakan Labview. Jurnal Nasional Teknik Elektro Dan Teknologi Informasi, 5(2), 129-134. Retrieved from https://dev.journal.ugm.ac.id/v3/JNTETI/article/view/2958
Section
Articles