Seismic Performance Evaluation of Irregular Auditorium Building based on ASCE 41-23

  • Ananda Elnish Fiqhunissa Department of Civil and Environmental Engineering, Gadjah Mada University, Yogyakarta, INDONESIA
  • Iman Satyarno Department of Civil and Environmental Engineering, Gadjah Mada University, Yogyakarta, INDONESIA
  • Angga Fajar Setiawan Department of Civil and Environmental Engineering, Gadjah Mada University, Yogyakarta, INDONESIA
  • Mariyana Aida Ab Kadir Department of Structure and Material, Faculty of Civil Engineering, University of Technology Malaysia, Johor Bahru, MALAYSIA
  • Muhamad Fauzi Darmawan Department of Civil and Environmental Engineering, Gadjah Mada University, Yogyakarta, INDONESIA
Keywords: New irregular building, Tier 3 evaluation, Linear dynamic procedure, Response spectrum analysis method, Linear time history analysis method

Abstract

This study discusses the seismic performance evaluation of an irregular auditorium building. The building is an educational facility which has roof span up to 46 meters, column height up to 10 meters, beam span up to 15 meters, cantilever up to 6.50 meters, 2 inclined columns with the angle up to 54.72°, and 1 transfer column with 1 transfer beam. The evaluation process was carried out using Tier 3 method with linear dynamic procedure which consisted of Response Spectrum Analysis (RSA) and Linear Time History Analysis (LTHA) according to ASCE 41-23 using SAP2000 subjected to short (S s ) and long (S ) period of earthquakes. The building is designed to Risk Category IV, which the target performance levels for structural components are Immediate Occupancy (IO) for Basic Safety Earthquake 1 for New Building (BSE-1N) and Life Safety (LS) for Basic Safety Earthquake 2 for New Building (BSE-2N). Even though the building had a torsional strength irregularity, the percentage of components with a Demand-Capacity Ratio value that did not meet the requirements was 9.87% of the total components; hence the linear procedure was assumed to be still applicable. Analyses showed that the average acceptance criteria ratio of the components with the RSA method was lower than with the LTHA method but the percentage of the components with acceptance criteria ratio exceeding 1 using RSA method was higher than using the LTHA method. In addition, the results indicated that the average performance level of the components was IO for BSE-1N and LS for BSE-2N, which both results had met the expected performance level targets. However, the maximum performance level of the components did not meet the IO performance level target for BSE-1N and did not meet the LS performance level target for BSE-2N.

References

ACI. 2019. Building Code Requirements for Structural Concrete (ACI 318-19) and Commentary (ACI 318R-19). Farmington Hills, Michigan. American Concrete Institute.

Adhitama, Yuliar Azmi. 2022. Evaluasi Kinerja Seismik Struktur Bangunan Eksisting Gedung Rumah Sakit 5 Lantai menurut ASCE 41-17. Yogyakarta. Gadjah Mada University.

ASCE. 2016. ASCE 7-16 Minimum Design Loads and Associated Criteria for Buildings and Other Structures. Reston, Virginia. American Society of Civil Engineers.

ASCE. 2017. ASCE 41-17 Seismic Evaluation and Retrofit of Existing Buildings. Reston, Virginia. American Society of Civil Engineers.

Chandrakar, Prakriti and Bokare, P. S. 2017. A Review – Comparison between Response Spectrum Method and Time History Method for Dynamic Analysis of Multistoried Building. Bhilai. RSR Rungta College of Engineering and Technology.

Jose, Jerin M., et al. 2021. Review of Analysis of Irregular Building. Kottayam. Mangalam College of Engineering.

Kumar, Nitin, et al. 2018. Comparative Study of Equivalent Lateral Force Method and Response Spectrum Method for OMRF Multistory Building. Meerut. Swami Vivekanand Subharti University.

Listyorini, Edy P., Agus, S. 2015. Evaluasi Kinerja Struktur Gedung dengan Analisis Time History (Studi Kasus: Gedung Rumah Sakit Bethesda Yogyakarta). Surakarta. Sebelas Maret University.

Lo, Bi, et al. 2020. Evaluation of Amplitude‑Scaled and Spectrum‑Matched Motions to Estimate Ground‑Motion Amplification Factors. Tiongkok. Harbin Institute of Technology.

Patil, Rashmi S., H. S. Vidyadhar, S. B. Patil. 2017. Seismic Analysis of Multistoried Building with and without Vertical Mass Irregularity. Kalaburagi, India. International Journal of Research Publications in Engineering and Technology (IJRPET).

Putra, Ardita Andana. 2021. Evaluasi Kinerja Struktur Bangunan Gedung Radiopoetro FK-KMK UGM dengan Ananlisis Pushover menggunakan SAP2000. Yogyakarta. Gadjah Mada University.

Ramdev, Prajapati, Prashant R. Barbude, A. P. Patil. 2021. Dynamic Analysis of Multistory Structure using Linear Time History Analysis. Maharashtra. Mumbai University.

Razzaq, Khattab S. A., Abbas H. M., Asala, A. D. 2019. A Review of Previous Studies on the Reinforced Concrete Corbels. Diyala, Iraq. Diyala University.

Sazzad, MD. M., et al. 2017. Effect of Mesh Size of Floor Slab against Lateral Loads while using Etabs Program. Bangladesh. Rajshahi University of Engineering and Technology.

Suryanto, Sarah E. 2018. Performance Based Seismic Design: Pendekatan Lebih Terukur dan Ekonomis untuk Perencanaan Bangunan Tingkat Tinggi Beton Bertulang. Yogyakarta. Gadjah Mada University.

Tim Pusat Studi Gempa Nasional. 2022. Peta Deagregasi Bahaya Gempa Indonesia untuk Perencanaan dan Evaluasi Infrastruktur Tahan Gempa. Jakarta. Kementrian Pekerjaan Umum dan Perumahan Rakyat.

Turker, Hakan T. 2020. A Modified Beam Theory for Bending of Eccentrically Supported Beams. Bursa. Bursa Uludag University.

Velamuri, A. and Y. Rajesh Kumar. 2019. Comparison of Response Spectrum, Time History and Matched Time History Method in Zone V And Zone IV Earthquake Zones of Multi Storied Building as Per Is 1893 2016. India. International Journal of Recent Technology and Engineering.

Zagade, Kalpak A., Aniket Patil, Abhijeet Galatage. 2021. A Review Paper on Time History Analysis/ Non Linear Dynamic Analysis of High Rise Building using ETABS. Pune, Maharashtra. International Journal of Creative Research Thoughts (IJCRT).

Zahran, Eiad Hafiz. 2016. Effect of GFRP Wraps on HSC Columns Strengthened with GFRP with Different Steel Ratio. India. International Journal of Engineering and Applied Sciences (IJEAS).

Published
2024-09-18
How to Cite
Fiqhunissa, A. E., Iman Satyarno, Angga Fajar Setiawan, Mariyana Aida Ab Kadir, & Darmawan, M. F. (2024). Seismic Performance Evaluation of Irregular Auditorium Building based on ASCE 41-23 . Journal of the Civil Engineering Forum, 10(3), 299-314. https://doi.org/10.22146/jcef.13306
Section
Articles