Gas Holdup and Gas-Liquid Mass Transfer Investigations In an Oscillatory Baffled Column

  • Taslim - Department of Chemical and Process Engineering University
  • Mohd Sobri Takriff Department of Chemical Engineering, University Kebangsaan Malaysia
Keywords: gas holdup, mass transfer coefficient, power density, superficial gas velocity

Abstract

Gas holdup and gas-liquid mass transfer were investigated in a vertical baffled column. Pure carbon dioxide (C02) was used as the dispersed phase and tap water was used as the continuous phase. Gas holdup and mass transfer rate of C02 were measured under semi-batch condition, while the liquid phase was measured in batch mode. Gas holdup was estimated as the volume fraction of the gas in the two-phase mixture in the column. Mass transfer was expressed in terms of the liquid-side volumetric mass transfer coefficient (kLa). The effects of oscillation frequency, oscillation amplitude and gas flow rate on gas holdup and mass transfer were also determined. The results showed that a significant increase in gas holdup and mass transfer could be achieved in an oscillatory baffled column compared to a bubble column. Gas holdup and mass transfer were correlated as a function of power density and superficial gas velocity.

References

Baird, M.H.I. & Stonestreet, P. "Energy Dissipation in Oscillatory Flow Within a Baffled Tube". Trans. I. ChemE., 73(A), 1995, 503-511.

Baird, M.H.I., Rama Rao, N.V.& Stonestreet, P. "Power Dissipation and Holup in a Gassed Reciprocating Baffle-PlateColumn".Trans. I. ChernE., 74(A), 1996,463-470.

Bouaifi,M., Hebrard, G., Bastoul, D. & Roustan, M. "A Comparative Study of Gas Holdup, Bubble Size, Interfacial Area and Mass Transfer Coefficients in Stirred Gas-Liquid Reactors and Bubble Columns". Chem. Eng. Processing, 40(2), 2001, 97-111.

Brunold, C.R., Hunn, J.C.B., Mackley, M.R. & Thomson, J.W. "Experimental Observations on Flow Patterns and Energy Looses for Oscillatory Flow in Ducts Containing Sharp Edges". Chem. Eng. Sci., 44(5), 1989, 1227-1244.

Deckwer, W.O., Burkhart, R. & Zoll, G. "Mixing and Mass Transfer in tall bubble columns". Chem. Eng. Sci., 29(11), 1974, 2177-2188.

Dickens, A.W., Mackley, M.R. & William, H.R. "Experimental Residence Time Distribution Measurements for Unsteady Flow in Baffled Tubes". Chem. Eng. Sci., 44(7), 1989, 1471-1479.

Jealous, A.C. & Johnson, H.E "Power Requirements for Pulse Generation in Pulse Column". Ind. Eng. Chem., 47(6), 1955, 1159-1166.

Hewgill, M.R., Mackley, M.R., Pandit, A.B. & Pannu, S.S. "Enhancement of Gas-Liquid Mass Transfer Using Oscillatory Flow in Baffled Tubes". Chem. Eng. Sci., 48(4), 1993, 799-803.

Linek, V., Benes, P.& Vacek, V. "Acritical Review and Experimental Verification of the Correct Used of the Dynamic Method for the Determination of Oxygen Transfer in Aerated Agitated Vessels to Water, Electrolyte Solutions and Viscous Fluids". Chem. Eng. J., 34, 1987, 11-34.

Mackay, M.E.,. Mackley, M.R. & Wang, Y. "Oscillatory Flow within Tubes Containing Wall or Central Baffles". Trans. I. ChemE., 71(A), 1991, 649-656.

Mackley, M.R. "Using Oscillatory Flow to Improve Performance". The Chemical Engineer. February, 1987, 18-20.

Mackley, M.R. "Process Innovation Using Oscillatory Flow within Baffled Tubes". Trans. I. ChemE., 69(A), 1991, 197-199.

Ni, X. & Gough, P. "On the Discussion of Dimensionless Groups Governing Oscillatory Flow in a Baffled Tube". Chem. Eng. Sci., 52(18), 1997,3209-3212.

Robert, E.P.L. "The Simulation of Chaotic Advection for Application to Process Engineering". Trans. I. ChemE., 69 (A), 1991,208-210.

Shah, Y.T., Deckwer, W.O., Kelkar, B.G. & Godbole, S.P. "Design Parameters Estimations for Bubble Column Reactors. AI.Ch.E.J., 28(3), 1982,353-379.

Published
2002-12-31
How to Cite
-, T., & Takriff, M. S. (2002). Gas Holdup and Gas-Liquid Mass Transfer Investigations In an Oscillatory Baffled Column. ASEAN Journal of Chemical Engineering, 2(1), 7-14. Retrieved from https://dev.journal.ugm.ac.id/v3/AJChE/article/view/7511
Section
Articles