Abstract


Curcumin possesses anticoagulant, anti-proliferative, and anti-inflammatory properties and is applicable to prevent in-stent restenosis. This research investigated curcumin coating with biodegradable chitosan polymer as a drug carrier universally made on Co-Cr L605 surface by the ultrasonic spray method. Three curcumin doses were implemented: low dose (150 μg of curcumin per sample), medium dose (300 μg of curcumin per sample), and high dose (480 μg of curcumin per sample). The metal surface morphologies before and after coating were examined by using a stylus profilometer and a scanning electron microscope (SEM). The result showed that coating films were formed fine and uniform with an average roughness level below 0.2 μm. The coating film structure characterization by Fourier-transform infrared (FTIR) spectroscopy showed that curcumin absorption spectra still occurred in the chitosan-curcumin coating, although chitosan strong absorption spectra were dominant.

Keywords


curcumin, stent, coating, ultrasonic spray.

Full Text:

PDF


References

Curcio A., Torella D., & Indolfi C., 2011, Mechanisms of smooth muscle cell proliferation and endothelial regeneration after vascular injury and stenting, Circulation Journal, Vol. 75, pp. 1287 – 1296

Fryer, R., Galustian, C., & Dalgelish, A., 2009, Recent advances and developments in treatment strategies against pancreatic cancer, Current Clinical Pharmacology, Vol. 4, pp. 102–112.

Erbel, R., Haude, M., Hopp, H. W., Franzen, D., Rupprecht, H. J., & Heublein, P, P., 2011, Coronary-artery stenting compared with balloon angioplasty for restenosis after initial balloon angioplasty, Survey of Anesthesiology, Vol. 43, pp. 195–196.

Herliansyah, M. K., Ilman, K. A., & Tontowi, A. E., 2017, Potential of curcumin as antiproliferative drug for developing drug eluting stent : a brief review, international conference on instrumentation, Commu- nications, Information Technology and Biomedical Engineering, Vol. 978, pp. 5386-3455.

Khan. W., Farah. S., & Domb. A.J., 2012, Drug eluting stents : developments and current status, Journal of Controlled Release, Vol. 161, pp. 703 – 712.

Livingston, M., & Tan, A., 2016, Coating techniques and release kinetics of drug-eluting stents, Journal of Medical Devices, vol. 10, pp. 010801-1 - 010801-8.

Martin, D. M., & Boyle, F. J., 2011, Drug-eluting stents for coronary artery disease: a review, Medical Engineering & Physics, Vol. 33, pp. 148–163.

Mendis S., Puska P., & Norrving Bo., 2011, Global atlas on cardiovascular disease prevention and control, World Health Organization.

Nurdjaman, I. H., 2003, Manfaat curcumin pada nyeri punggung bawah akut miofasial, Master Thesis, Universitas Gadjah Mada.

Pan, Ch. J., Tang, J. J., Weng, Y. J., Wang, J., & Huang, N., 2006, Preparation, characterization and anticoagulation of curcumin-eluting controlled biodegra- dable coating stents, Journal of Controlled Release, Vol. 116, pp. 42–49.

Peng, Z., & Liu, M., 2001, preparation of dense platinum-yttria stabilized zirconia and yttria stabilized zirconia films on porous la0.9sr0.1mno3 (LSM) substrates, Journal of the American Ceramic Society, Vol. 84, pp. 283–88.

Shahbazi, M. A., Hamidi, M., & Mohammadi‐Samani, S. (2013). Preparation, optimization, and in‐vitro/in‐vivo/ex‐vivo characterization of chitosan‐heparin nanoparticles: druginduced gelation. Journal of Pharmacy and Pharmacology, Vol. 65, pp. 1118-1133.

Tan C., & Schatz R.A., 2016, The history of coronary stenting, Intervention Cardiology Clinic, vol. 5, pp. 271 – 280.

Tontowi, A. E., Ikra, P., & Siswomihardjo, W. 2013. Mapping of coronary stent demand of several hospitals in Indonesia and its forecasting, Proc. of 2013 3rd Int. Conf. on Instrumentation, Communications, Information Technol., and Biomedical Engineering: Science and Technol. for Improvement of Health, Safety, and Environ., ICICI-BME, pp. 436–439.



DOI: https://doi.org/10.22146/jmpc.68281

Article Metrics

Abstract views : 1947 | views : 987

Refbacks

  • There are currently no refbacks.