USFDA-GUIDELINE BASED VALIDATION OF TESTING METHOD FOR RIFAMPICIN IN INDONESIAN SERUM SPECIMEN
Tri Joko Raharjo(1*), Tri Wahyudi(2), Sismindari Sismindari(3)
(1) Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Gadjah Mada, Sekip Utara, Yogyakarta 55281
(2) Faculty of Pharmacy, Universitas Gadjah Mada, Sekip Utara Yogyakarta 55281
(3) Faculty of Pharmacy, Universitas Gadjah Mada, Sekip Utara Yogyakarta 55281; Integrated Laboratory for Testing and Research (LPPT-UGM), Universitas Gadjah Mada, Sekip Utara Yogyakarta 55281
(*) Corresponding Author
Abstract
Regarding a new regulation from Indonesia FDA (Badan POM-RI), all new non patent drugs should show bioequivalence with the originator drug prior to registration. Bioequivalence testing (BE-testing) has to be performed to the people that represented of population to which the drug to be administrated. BE testing need a valid bio-analytical method for certain drug target and group of population. This research report specific validation of bio-analysis of Rifampicin in Indonesian serum specimen in order to be used for BE testing. The extraction was performed using acetonitrile while the chromatographic separation was accomplished on a RP 18 column (250 × 4.6 mm i.d., 5 µm), with a mobile phase composed of KH2PO4 10 mM-Acetonitrile (40:60, v/v) and UV detection was set at 333 nm. The method shown specificity compared to blank serum specimen with retention time of rifampicin at 2.1 min. Lower limit of quantification (LLOQ) was 0.06 µg/mL with dynamic range up to 20 µg/mL (R>0.990). Precision of the method was very good with coefficient of variance (CV) 0.58; 7.40 and 5.56% for concentration at 0.06, 5, 15 µg/mL, respectively. Accuracies of the method were 3.22; 1.94; 1.90% for concentration 0.06, 5 and 15 µg/mL respectively. The average recoveries were 97.82, 95.50 and 97.31% for concentration of rifampicin 1, 5 and 5 µg/mL, respectively. The method was also shown reliable result on stability test on freezing-thawing, short-term and long-term stability as well as post preparation stability. Validation result shown that the method was ready to be used for Rifampicin BE testing with Indonesian subject.
Full Text:
Full Text PdfReferences
[1] Maggi, N., Pasqualucci, C.R., Ballota, R., and Sensi, P., 1966, Chemotherapia, 11, 285.
[2] O’Hara, P., and Hicckey, A.J., 2000, Pharm. Res., 17, 955.
[3] Panchagnula, R., Sharma, A., and Agrawal, S. 2004, Pharm. Res., 50, 317–327.
[4] Evans, J.T., Parveen, A., Smith, G.E., Xu, L., Chan, E.W.C., Chan, R.C.Y., and Hawkey, P.M., 2009, J. Antimicrob. Chemother., 63, 2, 295-301.
[5] Shah, Y., Khanna, S., Jindal, K.C., and Dighe, V.S., 1992, Drug Dev. Ind. Pharm., 18, 14, 1589-1596.
[6] Badan POM-RI, 2005, Peraturan Kepala BPOM RI No. HK.00.05.1.3682 tentang Tata Laksana Uji Bioekivalensi
[7] Calleja, I., Blanco-Pr´ıeto, M.J., Ruz, N., Renedo, M.J., and Dios-Viéitez, M.C., 2004, J. Chromatogr. A, 1031, 289–294.
[8] Kumar, A.K.H., Chandra, I., Geetha, R., Chelvi, K.S., Lalitha, V., and Prema, G., 2004, Indian J. Pharmacol., 36, 4, 231-233.
[9] Liu, J., Sun, J., Zhang, W., Gao, K., and He, Z., 2008, J. Pharm. Biomed. Anal., 46, 2, 405-409.
[10] Agrawal, S., Singh, I., Kaur, K.J., Bhade, S.R., Kaul, C.L., and Panchagnula, R., 2004, J. Pharm., 276, 41–49.
[11] Agrawal, S., Singh, I., Kaur, K.J., Bhade, S.R., Kaul, C.L., and Panchagnula, R., 2004, Pharmacol. Res., 50, 317-327.
[12] Agrawal, S., Kaur, K.J., Singh, I., Bhade, S.R., Kaul, C.L., and Panchagnula, R., 2002, Int. J. Pharm., 233, 169-177.
[13] Panchagnula, R., and Agrawal, S., 2004, Int. J. Pharm., 271, 1–4.
[14] Panchagnula, R., Singh, I., Kaur, K.J., and Kaul, C.L., 1999, Methods Find Exp. Clin. Pharmacol., 21, 9, 625.
[15] Eurachem, 1998, The Fitness for Purpose of Analytical Methods A Laboratory Guide to Method Validation and Related Topics
[16] Center for Drug Evaluation and Research (CDER) and Center for Veterinary Medicine (CVM), 2001, Guidance for industry, bioanalytical method validation, Food and Drug Administration (FDA), U.S. Department of Health and Human Services.
DOI: https://doi.org/10.22146/ijc.21494
Article Metrics
Abstract views : 1446 | views : 1037Copyright (c) 2010 Indonesian Journal of Chemistry
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Indonesian Journal of Chemistry (ISSN 1411-9420 /e-ISSN 2460-1578) - Chemistry Department, Universitas Gadjah Mada, Indonesia.
View The Statistics of Indones. J. Chem.